1.
Article in English | LILACS-Express | LILACS | ID: biblio-1385750

ABSTRACT

ABSTRACT: The aim of this in vitro study was to evaluate measurement accordance using an electronic apex locator for estimation of working length in endodontics when different restorative materials for interim crown restoration are utilized. For this study, 13 single-rooted premolars with endodontic occlusal access cavity were prepared. To establish the working length of each tooth, these were mounted in alginate and with the help of an electronic foramen locator and endodontic file K-file # 15, the working length was established. This length was later compared to the estimated working lengths using different intermediate restoration materials. These materials were: Superior Chemfil, Ketac ™ Molar Easymix and Filtek z350 resin. In the electronic measurements, an acceptable tolerance range of variation up to ± 0.5 mm was considered. Highest discrepancies were considered erroneous. For these measurements, central tendency and dispersion were analyzed. The Bland-Altman method was used, and the ANOVA test with a significance level of p <0,05 for statistic difference. Regarding measurements' acceptability and the type of interim restoration material utilized, 7 were acceptable, and 6 were unacceptable for ChemFil Superior, 12 were acceptable and 1 unacceptable for Ketac™ Molar Easymix, and 11 were acceptable and 2 were unacceptable for Filtek Z350 composite resin. The average difference between all electronic measurements was 0.29 (± 0.44). Chemfill Superior showed the most prominent variation between measurements 0.58 (± 0.45). When using an electronic apex locator, measurements showed statistically significant differences depending on the interim restoration material of choice (p<0.05). In conclusion, the measurement accordance using electronic apex locator to estimation the working length is higher, however the electronic estimation of working length can be significatively affected by the material chosen for interim temporary restoration.


RESUMEN: El objetivo de este estudio in vitro, fue evaluar la concordancia de las estimaciones de longitud de trabajo mediante localizador electrónico de foramen, utilizando diferentes materiales de restauración intermedia coronaria. Para tales fines fueron preparados 13 premolares uniradiculares con cavidad de acceso oclusal endodóntico. Para establecer la a longitud de trabajo de cada diente, estos fueron montados en alginato y con la ayuda de un localizador electrónico de foramen y lima de endodoncia K-file #15 fue establecida la longitud de trabajo. Esta longitud fue comparada posteriormente con las longitudes de trabajo estimadas utilizando diferentes materiales de restauración in- termedia. Estos materiales fueron: Chemfil superior, Ketac™ Molar Easymix y resina Filtek z350. En las mediciones electrónicas, se consideró un rango de tolerancia aceptable de variación hasta ± 0,5 mm. Las discrepancias mayores se consideraron erróneas. Se calcularon medidas de tendencia central y la dispersión. Se utilizó el método de Bland- Altman y la prueba ANOVA con un nivel de significancia de p <0,05. Con respecto a la aceptabilidad de las mediciones y el tipo de material de restauración intermedia, 7 fueron aceptables y 6 fueron inaceptables para ChemFil Superior, 12 fueron aceptables y 1 inaceptable para Ketac ™ Molar Easymix, y 11 fueron aceptables y 2 fueron inaceptables para el compuesto Filtek Z350 resina. La diferencia promedio entre todas las mediciones electrónicas fue de 0,29 (± 0,44). Chemfil Superior mostró la mayor variación entre medicio- nes 0,58 (± 0,45). Las mediciones mostraron diferencias estadísticamente significativas dependiendo del material de restauración intermedio elegido (p <0,05). En conclusión, la concordancia en la estimación de la longitud de trabajo usando localizador electrónico de foramen es alta, sin embargo, puede verse afectada significativamente por el material de obturación intermedio.

2.
Rev. cient. odontol ; 8(3): e28, sept.-dic. 2020. tab
Article in Spanish | LILACS, LIPECS | ID: biblio-1253434

ABSTRACT

Objetivo: El propósito del estudio in vitro fue comparar la precisión de la longitud de trabajo de Root ZX mini, Proper Pixi, Woodpex III y Raypex 6 utilizando limas de acero inoxidable VDW C-Pilot n.º 15 y de níquel-titanio Maillefer n.º15. Materiales y métodos: Este estudio fue experimental in vitro. La muestra fue de treinta y cinco conductos mesiovestibulares de primeras molares inferiores, con cuatro localizadores apicales electrónicos Root ZX mini, Proper Pixi, Woodpex III y Raypex6. La longitud real se determinó con un calibrador Vernier digital y la medición electrónica se realizó utilizando limas de acero inoxidable y de níquel-titanio. Resultados: Al comparar la longitud real y longitud electrónica, no se encontró diferencias estadísticamente significativas (p < 0,05). Conclusiones: Se halló diferencias estadísticamente significativas al comparar la precisión de Root ZX mini, Proper Pixi, Woodpex III y Raypex 6 con limas de acero inoxidable; mientras que la precisión con limas de níquel-titanio no se vio afectada. (AU)


Objective: The purpose of this study was to compare the precision of the working length of Root ZX mini, Proper Pixi, Woodpex III and Raypex 6 using VDW C-Pilot No. 15 with Maillefer nickel titanium No. 15 and stainless steel files in mesiovestibular ducts of first lower molars. Materials and methods: This was an experimental in vitro study, including 35 mesiobuccal canals of lower first molars. The real length of 4 electronic apical locators, Root ZX mini, Proper Pixi, Woodpex III and Raypex6, was determined with a digital Vernier caliper, and electronic measurements were recorded using stainless steel and nickel titanium files. Results: There were no statistically significant differences between the real and the electronic lengths of the different tools studied (p <0.05). Conclusions: Statistically significant differences were obtained when comparing the precision of Root ZX mini, Proper Pixi, Woodpex III and Raypex 6 with stainless steel files, while the precision of nickel titanium files was not affected. (AU)


Subject(s)
Humans , Titanium , Dental Materials , Molar , Nickel , In Vitro Techniques
3.
Int. j. odontostomatol. (Print) ; 14(1): 124-130, mar. 2020. graf
Article in Spanish | LILACS | ID: biblio-1056511

ABSTRACT

RESUMEN: En la historia de la Endodoncia, se han utilizado distintos métodos para determinar la longitud de los canales radiculares, como sensación táctil y radiografías. Últimamente, han adquirido gran importancia los localizadores apicales electrónicos, por su gran precisión. Actualmente se ha incorporado el uso de imagenología con Cone Beam. Debido a que existen muchas formas de medir dicha longitud, es necesario ponerlos a prueba y ver si se asemejan a la técnica gold estándar definida en la literatura como el localizador electrónico de foramen apical. El propósito de esta investigación es determinar si existen diferencias estadísticamente significativas en la medida de la longitud de trabajo entre el localizador electrónico de foramen apical, y el uso de Cone Beam procesado con el software 3D endo de Dentsply Sirona. Para esto, se seleccionaron 30 premolares extraídos; se les tomó un Cone Beam para ser analizados con el software 3D endo y medir la longitud de trabajo. Una vez hecho esto, se realizó manualmente cavidad de acceso y se preparó el tercio cervical con fresas Gates Glidden 1 y 2; luego, los dientes fueron colocados en un modelo Pro Train, que asemejó las propiedades de los dientes en la cavidad oral, para permitir el uso del localizador electrónico de foramen y determinar la longitud de trabajo. Una vez obtenidos los datos, fueron comparados a través del Test de Proporciones (p=0.05 hipotético), dando como resultado p=0,2 lo que indica que no existen diferencias estadísticamente significativas en la medida de la longitud de trabajo entre ambos métodos.


ABSTRACT: Various methods have been used in the history of endodontics, to determine the length of the root canals (working length), such as tactile sensation and X-rays. Recently, apical locators have acquired importance, due to their precision. The use of Cone Beam has now also been incorporated. Because there are many ways to measure this length, it is necessary to test them and see if they resemble the standard gold measurement technique defined in the literature as the electronic apex locators. The purpose of this research is to determine whether there are statistically significant differences in the working length between the electronic apex locators, and the use of Cone Beam processed with the Software 3D Endo by Dentsply Sirona. For this, 30 extracted pre-molars were selected, for Cone Beam tomography and 3D endo Software analysis, to measure the working length. Once this was carried out, cavity preparation was performed manually, and the cervical third approached with gates glidden drills 1 and 2. Subsequently, the teeth were placed in a Pro Train model, which resembled the properties of the teeth in the oral cavity, to allow the use of the electronic apex locators to determine the working length.Once the data were obtained, they were compared through the proportions Test (p = 0.05 hypothetical), resulting in p = 0.2, indicating that there are no statistically significant differences in the working length between the two methods.


Subject(s)
Humans , Tooth/anatomy & histology , Software , Imaging, Three-Dimensional , Surgery, Computer-Assisted/methods , Endodontics/standards , Magnetic Resonance Imaging/methods , Chile , Cone-Beam Computed Tomography/methods , Odontometry
4.
Rev. Asoc. Odontol. Argent ; 107(1): 10-18, ene.-mar. 2019. ilus, tab
Article in Spanish | LILACS | ID: biblio-998624

ABSTRACT

Objetivo: Evaluar ex vivo la confiabilidad de la medición electrónica de la longitud de trabajo obtenida por dos localizadores apicales en forámenes inmaduros simulados. Materiales y métodos: 20 incisivos centrales superiores humanos extraídos con conductos rectos se dividieron en dos grupos de 10 cada uno. En el grupo A, los conductos y los forámenes se prepararon paralelos hasta un calibre #100. En el grupo B, se procedió de manera similar al grupo A, pero los forámenes se prepararon divergentes. Las raíces se recubrieron con una membrana de intestino porcino simulando el ligamento periodontal y se insertaron individualmente en 20 orificios preparados en la tapa de una cuba de acrílico que contenía hueso bovino particulado humedecido. La tapa fue reposicionada en la cuba cuidando que las raíces quedaran sumergidas en el hueso. Mediante una lima K de tercera serie se determinó la longitud de trabajo con los localizadores apicales RootZx y Mini Apex. Luego, se retiró la tapa con los dientes y las membranas, se los preparó hasta un calibre #120 y se midieron nuevamente. Se repitió el procedimiento preparando los forámenes hasta un calibre #140. Se determinó la longitud de trabajo cuando la pantalla de los localizadores apicales marcaba 0,5. Resultados: Las diferencias entre localizadores apicales no fueron significativas, pero sí lo fueron entre ambos tipos de forámenes al prepararlos hasta un calibre #140. Conclusiones: La medición electrónica ex vivo en dientes con forámenes inmaduros simulados fue confiable excepto cuando se prepararon con calibre #140 (AU)


Aim: To evaluate ex vivo the reliability of two apical electronic localizers to determine the working length in teeth with simulated immature foramens. Materials and methods: Twenty extracted upper central human incisors with straight root canals were assigned to two groups of 10 teeth each. In group A, the canal walls and foramens were prepared parallel to a size #100. In group B, the canals were prepared similar but the foramens were divergent. Each root was surrounded with a porcine intestine membrane simulating the periodontal ligament and then placed through holes prepared on the cover of an acrylic box filled with humid particulate bovine bone. The cover holding the teeth was repositioned taking care that the roots were submerged into the particulate bone. A third series K-file along with Root Zx or Mini Apex apical electronic localizers was used to determine the electronic working length. The cover with the teeth and membranes was then removed, the canals were over-prepared to a #120 size file and the electronic working length was measured, then the foramens were widened to a #140 size and the measurements were repeated. The working length was determined when the apical electronic localizers showed 0.5 on the screen. Results: No significant differences were observed between the apical electronic localizers, while significant differences were detected between both types of foramens when prepared to a size #140 (AU)


Subject(s)
Humans , Tooth Apex , Freeze Drying , Odontometry , Tooth Root , Data Interpretation, Statistical , Electric Impedance , Acellular Dermis
5.
Rev. Asoc. Odontol. Argent ; 106(3): 102-105, sept. 2018. ilus
Article in Spanish | LILACS | ID: biblio-964474

ABSTRACT

El propósito de este artículo es presentar un modelo didáctico ex vivo para la determinación electrónica de la longitud de trabajo, mediante el empleo de elementos con propiedades similares a los tejidos perirradiculares humanos. El modelo es especialmente aplicable a la enseñanza de grado y posgrado y permite observar paso a paso, en el interior del conducto radicular, de qué manera se desarrolla el proceso de medición electrónica (AU)


The purpose of this article is to describe an ex vivo didactic model to determine the working length using elements with properties similar to periradicular human tissues that are available. The model is specifically designed to be used by undergraduate and graduate students and allowed step by step visual observation of the operation of electronic canal length measuring devices (AU)


Subject(s)
Humans , Animals , Cattle , Models, Educational , Tooth Apex , Education, Dental, Graduate , Education, Predental , Periodontal Ligament , Swine , Bone Transplantation , Electric Impedance , Intestines
6.
Rev. odontol. mex ; 22(2): 77-81, abr.-jun. 2018. graf
Article in Spanish | LILACS | ID: biblio-961596

ABSTRACT

Resumen: Objetivo: Evaluar la precisión de Raypex 6 para localizar el foramen y ubicarse en la zona cemento dentina conducto (CDC) en conductos de molares inferiores por medio de diafanización. Material y métodos: 52 conductos permeables de 20 molares inferiores extraídos inmersos en alginato fueron utilizados. Se realizó abertura coronaria, localización, permeabilización e irrigación con hipoclorito de sodio al 5.25%. Con el localizador electrónico Raypex 6 se obtuvo conductometría electrónica. Se introdujo lima tipo K #15 o 20 en cada muestra que tenía el clip labial inserto en alginato. La pantalla del dispositivo indicó la posición del foramen apical en la barra roja y se procedió a reajustar la posición de la lima K en las dos primeras barras amarillas y la lima se fijó con resina acrílica. Los dientes se diafanizaron por medio de la técnica de ácido nítrico y se mantuvieron en salicilato de metilo. Las muestras se analizaron con microscopio clínico a 16x y de manera subjetiva se asignó el valor de preciso, si la punta de la lima se ubicó entre 0 a -0.5 mm, fuera o positivo (+) si la lima estuvo +0.1 mm o más y corto o negativo (-) si fue de -0.51 mm o menos con respecto al foramen apical. Resultados: De las 52 muestras analizadas, se encontraron 40 precisas, siete largas y cinco cortas. La estadística descriptiva demostró 76.9% de precisión. Conclusión: La longitud de trabajo electrónica con Raypex 6 mostró una adecuada precisión en conductos mesiales de molares inferiores.


Abstract: Objective: To assess precision of Raypex 6 to locate foramen and establish placement in the canal -dentin-cement (CDC) area in lower molar canals by means of diaphanization. Material and methods: 52 permeable canals from 20 extracted lower molars immersed in alginate were used. Crown opening, location, permeabilization and irrigation with 5.25% sodium hypochlorite were performed. Electronic conductometry was obtained with Raypex 6 electronic locator. A K #15/20 file type was inserted in all samples which had labial clip inserted in alginate. The device's screen indicated position of the apical foramen in the red bar, K files position was readjusted in the first two yellow bars, the file was then fixated with acrylic resin. Teeth were diaphanized by means of the nitric acid technique; teeth were kept in methyl salicylate. Samples were analyzed with clinical microscope at 16x, they were subjectively assigned a value called precise when the tip of the file was located at 0-0.5 mm, external or positive (+), when the file was +0.1 mm or more, and short or negative (-) when it was -0.51 mm or less with respect to the apical foramen. Results: Of the 52 analyzed samples, 40 were found to be precise, seven long and five short. Descriptive statistics showed 76.9% precision. Conclusion: Electronic working length with Raypex 6 showed suitable precision in mesial canals of lower molars.

7.
Rev. Asoc. Odontol. Argent ; 106(2): 44-50, abr.-jun. 2018. ilus, tab
Article in Spanish | LILACS | ID: biblio-912521

ABSTRACT

Objetivo: Evaluar el ajuste y la adaptación apical de los conos de gutapercha de cuatro diferentes sistemas de instrumentación y obturación endodóntica en conductos curvos simulados. Materiales y métodos: Se emplearon 4 Endo Training Blocks (Dentsply Sirona) con conductos curvos simulados, instrumentados hasta el límite de trabajo, fijado en el orificio de salida del conducto. Con ese propósito se empleó un tope metálico confeccionado ad hoc, ajustado en la concavidad de la salida del conducto, a fin de asegurar el límite de la instrumentación en todos los bloques de trabajo. El tope metálico se mantuvo en la posición por medio de una morsa de mesa. Los conductos fueron permeabilizados con una lima tipo K #10 (Dentsply Sirona). A continuación, se procedió con los protocolos de instrumentación de los sistemas por evaluar en cada Endo Training Block. Se emplearon los sistemas ProTaper Next (Dentsply Sirona), ProTaper Gold (Dentsply Sirona), WaveOne Gold (Dentsply Sirona) y Reciproc Blue (VDW) de acuerdo con las especificaciones del fabricante (grupos 1, 2, 3 y 4 respectivamente). Los conductos fueron irrigados con agua destilada a cada cambio de instrumento y al finalizar la preparación, y secados con conos de papel. Luego se evaluaron, en el respectivo Endo Training Block, el ajuste y la adaptación apical a la longitud de trabajo de 10 conos de gutapercha del sistema correspondiente. Para la evaluación del ajuste, se introdujeron los conos de gutapercha en el conducto simulado respectivo y se elevaron ambos hasta 10 cm de altura, manteniéndolos durante 10 segundos. Cuando se conservaban en esa situación, se consideraba que el cono ajustaba; si se desprendían antes de ese lapso, se establecía la falta de ajuste. Así mismo, se constató en cada caso su adaptación apical a la longitud de trabajo con un microscopio clínico operativo a 8,5X. Para la evaluación total se consideraron las siguientes categorías: 1, el cono de gutapercha llegaba a la longitud de trabajo y ajustaba; 2, el cono de gutapercha llegaba a la longitud de trabajo, pero no ajustaba; 3, el cono de gutapercha no llegaba a la longitud de trabajo; y 4, el cono de gutapercha sobrepasaba la longitud de trabajo. Resultados: Entre los grupos 1, 3 y 4 no se observaron variables intrasistemas de ajuste y adaptación apical a la longitud de trabajo. En el grupo 2 sí las hubo, pero la diferencia entre grupos no fue significativa (P>0,05). Conclusiones: De los cuatro sistemas utilizados, en tres de ellos el empleo de un cono único de gutapercha garantizó, en todas las pruebas, la adaptación y el ajuste a la longitud de trabajo (AU)


Aim: To evaluate in the tugback and apical adaptation at the working length of four different mechanized systems gutta-percha cones in simulated curved canals. Materials and methods: Four Endo Training Blocks (Dentsply Sirona) with simulated curved canals were instrumented up to the working length established at the orifice located in the canal exit. A metal stop was adjusted in the concavity present at the exit of the canal to ensure the working length during instrumentation in all blocks. The metal stop was maintained using a table walrus. Canal patency was achieved with a #10 K file (Dentsply Sirona). Then the instrumentation protocols for the different systems were performed in each Endo Training Block. ProTaper Next (Dentsply Sirona), ProTaper Gold (Dentsply Sirona), WaveOne Gold (Dentsply Sirona) and Reciproc Blue (VDW) were used according to the manufacturers' instructions (groups 1, 2, 3 and 4 respectively). The canals were irrigated with distilled water between instruments and at the end of the preparation and dried with paper points. Then, the tugback and the apical adaptation at the working length of 10 gutta-percha cones of each system were evaluated in the corresponding Endo Training Block. For the tugback analysis, the gutta-percha cones were introduced in the respective simulated canal and both were raised up to 10 cm in height, holding them for 10 seconds. If the cones remained intact in their position, it was considered that the cone tugback was appropriate, if the cones were detached, a lack of tugback was considered. Likewise, a clinical operating microscope at 8.5X was used to confirm the apical adaptation to the working length in each case. For the overall evaluation the following categories were considered: 1, the gutta-percha cone reached the working length with tugback; 2, the gutta-percha cone reached the working length without tugback; 3, the gutta-percha cone did not reach the working length; 4, the gutta-percha cone exceeded the working length. Results: In three groups 1, 3 and 4 they were not found intra-systems variables in the tugback at the working length. In one group there were observed intra-systems variables but the differences between groups were not statistically significant (P>0.05) (AU)


Subject(s)
Dental Pulp Cavity , Gutta-Percha , Root Canal Obturation , Root Canal Preparation , Tooth Apex , Dental High-Speed Equipment , Models, Dental , Data Interpretation, Statistical
8.
Rev. Asoc. Odontol. Argent ; 106(1): 25-29, mar. 2018. ilus, tab
Article in Spanish | LILACS | ID: biblio-904858

ABSTRACT

Objetivo: Evaluar los efectos de la variación del haz central de rayos X al determinar la longitud de trabajo. Materiales y métodos: Se emplearon 32 raíces mesiales de primer molar inferior divididas en dos grupos, según la clasificación de Vertucci: tipo II (n=16) y tipo IV (n=16). Se tomaron radiografías en sentido vestíbulo-lingual, orto-radial, mesio-radial a 5o y a 10o, y disto-radial a 5o y a 10o. En cada toma radiográfica se midieron las distancias entre los instrumentos a nivel de los tercios cervical, medio y apical, antes y luego de instrumentar los conductos. Resultados: Los análisis estadísticos demostraron que en ambos grupos las mediciones simétricas disto-radial y mesio- radial a 5o y a 10o no diferían significativamente. Conclusión: En dientes con más de un conducto radicular, al fijar la longitud de trabajo, se recomienda variar la incidencia del haz de rayos X en no más de 10o hacia mesial o distal (AU)


Subject(s)
Humans , Odontometry , Radiography, Dental , Tooth Root , Analysis of Variance , Molar , Root Canal Preparation , Data Interpretation, Statistical
9.
Rev. Asoc. Odontol. Argent ; 105(2): 36-41, jun. 2017. tab, ilus
Article in Spanish | LILACS | ID: biblio-908055

ABSTRACT

Objetivo: evaluar la capacitación y los resultados del uso de localizadores del foramen en un curso preclínico destinado a alumnos de grado de la Escuela de Odontología de la Universidad del Salvador / AsociaciónOdontológica Argentina, entre 2005 y 2016. Materiales y métodos: Se emplearon 2053 incisivos, caninos y premolares inferiores y superiores humanos extraídos. Los dientes se montaron de modo tal que sus raí-ces quedasen sumergidas en una solución salina, utilizando dos métodos: a) tubos de plástico, b) modelos que simulan la arcada dentaria. Se realizaron los accesos coronarios al conducto radicular de forma convencional y se prepararonlos tercios cervical y medio. Para determinar la longitud de trabajo, se introdujo una lima tipo K de calibre acorde con el conducto radicular, ajustando en ella el terminal del localizador electrónico del foramen. El terminal labial se sumergió en la misma solución salina en que se encontraban las raíces dentarias. En la mayoría de los dientes se empleó, parala determinación, la técnica de ingreso, y en los restantes, la de regreso. El nivel de penetración se estableció con la señal lumínica y/o sonora de 0,5. Se ajustó el tope del instrumento al borde de referencia y se obtuvo una imagen radiográfica periapical del diente evaluado. Se retiró el instrumento del conducto radicular y se midió desde su punta hasta el tope respectivo. Las medidas obtenidas con los localizadores electrónicos del foramen se compararon con las conductometrías radiográficas, considerando una tolerancia de 0,5 mm. Para la evaluación estadística, se tomó en cuenta el cálculo de intervalo deconfianza (95 por ciento) realizado a partir de la distribución binomial.Resultados: De los 2053 dientes en los cuales se determinó la longitud de trabajo, 1743 (84,9 por ciento) fueron consideradas medidas correctas, y 310 (15,1 por ciento), incorrectas...


Aim: To assess the training process and results of the useof electronic apex locators in an Aim: To assess the training process and results of the useof electronic apex locators in an undergraduate preclinicalcourse for students from the University del Salvador / AsociaciónOdontológica Argentina between 2005 and 2016.Materials and methods: Two thousand fifty threeextracted human incisors, canines, maxillary and mandibularbicuspid teeth were used. The teeth were mounted withthe roots submerged in saline solution using two methods: a) plastic tubes, b) models simulating the dental arch. Conventionalcoronal access to the root canal was performedand the cervical and middle portions of the root canal wereflared. To determine the working length a K-file with a caliberaccording to the root canal was selected for each tooth andintroduced in the root canal with the clip adjusted in the file.The labial clip was immersed in the model saline solution. Inthe majority of the teeth the advanced and withdrawal techniquewas employed. The level of penetration was establishedusing the light and/or the acoustic signal at 0.5. Then, the rubberstop was adjusted to the reference line and a radiographwas obtained. The instrument was removed and measuredfrom its tip to the rubber stop. The measurements obtainedwith the electronic apex locators were compared with thoseobtained from the X rays considering a tolerance of 0.5 mm.For the statistical evaluation, 95% confidence intervals werecalculated using the binomial distribution.Results: Out of 2053 teeth in which the working lengthwas determined, 1743 (84.9%) were considered correct measurementsand 310 (15.1%) incorrects...


Subject(s)
Humans , Education, Predental/methods , Endodontics/education , Odontometry/methods , Tooth Apex/anatomy & histology , Bicuspid/anatomy & histology , Cuspid/anatomy & histology , Electric Impedance/therapeutic use , Incisor/anatomy & histology , Data Interpretation, Statistical
10.
Rev. ADM ; 73(3): 133-138, mayo-jun.2016. ilus, tab
Article in Spanish | LILACS | ID: lil-795805

ABSTRACT

El propósito de ese estudio fue evaluar in vivo la determinación de la longitud de trabajo utilizando el localizador apical electrónico Raypex 6. Material y métodos: Fueron determinadas la longitud de trabajo electrónica (Raypex 6) y radiográfica de 249 conductos radiculares de 125 pacientes con indicación de realizar tratamiento endodóntico. Los pacientes fueron atendidos según los protocolos clínicos habituales. La evaluación fue realizada en dos fases con dos niveles de aceptación, uno con una tolerancia de ± 0.5 mm y otra no. Resultados: En la fase 1 de nivel de tolerancia de evaluación, las mediciones fueron consideradas adecuadas (± 0.5 mm) en el 96.4 por ciento (93.3-98.3), cortos (- 0.5/1 mm) el 1.6 por ciento (04-4) y pasados (+ 0.5/1 mm) el 2 por ciento (0.7-4). Mientras que en la fase 2 de nivel de tolerancia de evaluación para las mediciones consideradas adecuadas (sin rango de tolerancia) fue de un 86.4 por ciento (81.5-91), cortos (- 0.5/1 mm) el 4 por ciento (2-7.8) y pasados (+ 0.5 y a 1 mm) el 9 por ciento (6-13.5). No fueron encontradas diferencias significativas al considerar eldiagnóstico y el género masculino o femenino. Conclusiones: Bajo lascondiciones en que se realizó este estudio la utilización del localizadorapical electrónico Raipex 6 ofreció una aceptable confiabilidad clínica en los dos niveles de tolerancia evaluados...


Subject(s)
Humans , Tooth Apex/anatomy & histology , Dental Instruments , Electric Impedance , Odontometry/instrumentation , Odontometry/methods , Root Canal Preparation/instrumentation , Data Interpretation, Statistical
11.
Odontol. vital ; jun. 2016.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1506802

ABSTRACT

El profesional en Endodoncia se plantea el dilema de hasta qué punto deben penetrar los instrumentos dentro del conducto. Por esta razón, la longitud real de las diferentes piezas dentales en distintas etnias y zonas geográficas de un mismo país es un dato importante y característico. Este estudio se realizó por medio de un análisis tomográfico en piezas extraídas. Se tomó una muestra representativa de las siete provincias de Costa Rica, utilizando 1470 raíces de 980 piezas dentales, 70 piezas superiores e inferiores, mostrando 210 raíces en su totalidad por provincia. Se logró determinar las longitudes reales de las diferentes piezas dentales de los costarricenses. De acuerdo con la metodología utilizada, la muestra fue probabilística de tipo estratificado, con el fin de asegurar una representación de cada una de las provincias del país; se recolectaron piezas dentales en clínicas dentales privadas y públicas. Los resultados reflejan piezas dentales con medidas que se asemejan a otros estudios realizados en otras partes del mundo.


The great dilemma for the practitioner in endodontics is how far to penetrate with the instruments within the duct. For this reason, the real longitude of the different teeth in various ethnias and geographic zones of the same country is an important and characteristic data. This research was done through a tomographic analysis of the extracted teeth. A representative sample of the seven provinces of Costa Rica was taken, using 1470 roots of 980 teeth, 70 superior teeth and inferior, giving 210 roots in total per province. It was possible to determine the real longitudes of the different teeth of the costaricans. According to the methodology used, the sample was probable of the stratified type with the objective goal of assuring a representation of each one of the provinces of the country; the dental pieces were collected through private and public dental clinics. The results reflect teeth with similar measurements to other studies done in other parts of the world.

12.
Rev. Asoc. Odontol. Argent ; 104(1): 16-21, mar. 2016. ilus, tab
Article in Spanish | LILACS | ID: lil-789830

ABSTRACT

Objetivo: valorar la concordancia entre las mediciones realizadas con un dispositivo de localización apical electrónica y las registradas mediante conductometría radiográfica. Materiales y métodos: fueron determinadas las longitudes de trabajo de manera electrónica (RayPex 6, VDW, Alemania) y radiográfica de 249 conducto radiculares correspondientes a 125 pacientes a los que se había indicado tratamiento endodóntico. Estos fueron atendidos según los protocolos clínicos habituales. Resultados: la prueba de t utilizada demostró que la diferencia media entre las mediciones no era significativamente distinta de 0. Los resultados para el coeficiente de correlación interclase y el correspondiente intervalo de confianza indican una concordancia de 0,991 para un intervalo de confianza de 95 por ciento. Concusiones: bajo las condiciones en que fue realizado este estudio, la concordancia entre los valores otenidos con los métodos de determinación de la longitud de trabajo electrónico y radiográfico fue muy buena


Subject(s)
Humans , Male , Female , Tooth Apex/anatomy & histology , Tooth Apex , Dental Pulp Cavity/anatomy & histology , Dental Instruments , Odontometry/methods , Electric Impedance , Radiography, Dental , Data Interpretation, Statistical
13.
Int. j. morphol ; 33(3): 1136-1140, Sept. 2015. ilus
Article in English | LILACS | ID: lil-762598

ABSTRACT

Within the procedures involved in a successful endodontic treatment is the working length (WL) determination. The root canal end must be detected accurately, and a precise control of the WL must be maintained. There are several methods to determine WL. Researchers have published the average teeth length (ATL) to the human permanent dentition. These measurements are used as an anatomical reference. If the WL is evaluated using a radiographic image, it is accepted as clinical success if the limit of the canal sealing is 1 mm coronal to the root apex. One method to determine WL is based in substract 1 mm to ATL. Another method widely used, assert to achieve a more precise WL determination, through the use of an electronic apex locator (AL). Nevertheless, published measures of ATL are still used as anatomical reference, and are used to determine WL in the absence of an AL. The aim of this study was to determine the average WL of second molars and premolars with endodontic treatment indication using a PropexII® AL, and compare these measurements to WL determination using ATL method. A descriptive cross-sectional study with a non-random sample of consecutive cases was executed. Results showed that there were no statistically significant differences between the WL obtained with AL and ATL method in studied teeth, except mesio-buccal canal of second maxillary molars (19.94 mm average using AL, 1.54 mm greater than ATL method 18.40 mm; p= 0.002). The ATL method to determine WL could be used to determine the WL of second molars and premolars in studied population. Further research should be performed to determine if ATL method is safe and reliable to be used in absence of an AL or in patients where this instrument cannot be used.


Entre los procedimientos involucrados en un tratamiento endodóntico exitoso está la determinación de longitud de trabajo (LT). Esta debe mantenerse durante todo el tratamiento, y el extremo del canal radicular (CR) debe detectarse con precisión. Existen varios métodos para determinar LT; los investigadores han publicado la longitud total promedio (LTP) de la dentición permanente humana. Estas mediciones se utilizan como referencia anatómica. Si LT se evalúa usando una imagen radiográfica, se acepta como éxito clínico cuando el límite de la obturación radicular queda 1 mm coronal al ápice radicular. Un método para determinar LT se basa en restar 1 mm a la LTP. Otro método, que permite una determinación de LT más precisa, se realiza utilizando un localizador apical electrónico (LA). Pese a esto último, las medidas publicadas de LTP todavía se utilizan como referencia anatómica, para determinar LT en ausencia de un LA. El objetivo fue determinar LT promedio de los CR de segundos molares y premolares con indicación de endodoncia utilizando LA PropexII®, y comparar estas mediciones con la LT determinada utilizando el método de LTP. Se realizó un estudio descriptivo de corte transversal con una muestra no probabilística de casos consecutivos. No hubo diferencias estadísticamente significativas entre la LT obtenida con LA y el método LTP en los dientes estudiados, salvo en los canales mesio-bucales de segundos molares superiores (19,94mm promedio usando LA, 1,54 mm mayor que el método LTP: 18,40 mm; p= 0,002). El método para definir LT a través de LTP podría utilizarse para determinar LT de segundos molares y premolares en la población estudiada. Se requieren investigaciones posteriores para determinar si el método que utiliza LTP es confiable para ser utilizado en ausencia de un LA o en pacientes en los que este instrumento no pueda ocuparse.


Subject(s)
Humans , Male , Female , Dental Pulp Cavity/anatomy & histology , Molar/anatomy & histology , Odontometry/methods , Tooth Apex/anatomy & histology , Cross-Sectional Studies , Electrical Equipment and Supplies , Odontometry/instrumentation
14.
J. oral res. (Impresa) ; 4(4): 249-254, ago.2015. ilus, tab
Article in English | LILACS | ID: lil-779226

ABSTRACT

This study was to evaluate in vivo the accuracy of three electronic apex locators (EALs) in determining working length (WL) using hand files and a wear technique. Thirty two premolars that were completely formed apically and that were scheduled for extraction for orthodontic reasons from patients between ages of 15 and 20 years old were included. Electronic measurement of WL was performed using the EAL according to the manufacturer’s instructions. The following three EAL were used: A. Root ZX II; B. Raypex 5, and C. Propex II. There were significant difference (p=0.0002) when comparing median differences among the three EAL. Statistical analysis revealed significant differences between Root ZX II vs. Raypex 5 and Root ZX II vs. Propex II (p=0.0044; p=0.0002), while between aypex 5 and Propex II, there were no statistically significant differences with respect to the accuracy of the EAL in determining WL (p=0.1087). The present findings suggest that Root ZX II presented the highest agreement rate for determining the final WL...


Estudio fue evaluar in vivo la exactitud de tres localizadores apicales electrónicos(LAEs) para determinar la longitud de trabajo (LT) usando instrumentos manuales y una técnica de desgaste. Treinta y dos premolares con formación apical completa e indicados para extracción por razones ortodóncicas de pacientes de edad entre 15 y 20 años fueron incluidos en el estudio. Seusaron tres LAE; A. Root ZX II; B. Raypex 5, y C. Propex II. Se encontraron diferencias significativas (p=0.0002) cuando se compararon las medianas entre los tres LAE. El análisismostró diferencias entre Root ZX II vs. Raypex 5 y Root ZX II vs. Propex II (p=0.0044; p=0,0002), mientras queentre Raypex 5 y Propex II, no se encontraron diferencias estadísticamente significativas en la determinación de la LT (p=0.1087). Los presentes hallazgos sugieren que Root ZX II mostró la mayor exactitud para determinar la LT final...


Subject(s)
Humans , Male , Adolescent , Adult , Female , Young Adult , Tooth Apex/anatomy & histology , Dental Pulp Cavity/anatomy & histology , Odontometry/instrumentation , Root Canal Preparation/instrumentation , Electrical Equipment and Supplies
15.
Rev. Asoc. Odontol. Argent ; 101(3): 91-96, sept. 2013. tab, ilus
Article in Spanish | LILACS | ID: lil-691120

ABSTRACT

Objetivo: el propósito de este trabajo fue evaluar "ex vivo" la confiabilidad de tres localizadores apicales electrónicos (LAE) en la determinación de la longitud de trabajo. Materiales y métodos: se utilizaron 20 incisivos centrales superiores humanos extraídos, con un solo conducto radicular y con ápice completamente desarrollado. Tras realizarse el acceso coronario, las piezas fueron colocadas en un recipiente de vidrio de 50 x 30 cm, previamente rellenado con alginato preparado con solución salina. Se establecieron tres grupos experimentales, uno para cada LAE: Grupo 1: Root ZX II (J. Morita., Kyoto, Japón). Grupo 2: ProPex II (Dentsply Maillefer, Ballaigues, Suiza). Grupo 3: iPex (NSK, Nakanishi Inc., Kakuma Tochigi, Japón). En todos los casos se utilizaron las mismas piezas dentarias. Con una lima tipo K #15 adosada a al sonda del localizador, se determinó la longitud de trabajo en cada especimen. La lima fue introducida hasta que la pantalla del localizador señaló que ésta se encontraba a una longitud adecauda, de acuerdo con las indicaciones del fabricante. Luego de cada medición electrónica, se realizó una radiografía de control, manteniendo la lima en esa posición. Los datos fueron registrados y comparados estadísticamente por medio de las pruebas de Friedman y de Tukey. El nivel de significancia establecido fue de P<0,05. Resultados: la comparación entre las mediciones obtenidas con los localizadores ROot ZX II y ProPex II revelaron diferencias estadísticamente significativas (P<0,05). Entre las obtenidas con el Root ZX II y el iPex no hubo diferencias significativas (P>0,05). Y entre las obtenidas con el ProPex II y el iPex tampoco las hubo (P>0,05). La concordancia en la determinación de la longitud de trabajo entre los 3 LAE fue sólo del 15 por ciento. Conclusión: bajo las condiciones en que fue realizado este estudio, los LAE utilizados arrojaron diferencias en las mediciones realizadas en un mismo diente.


Subject(s)
Humans , Tooth Apex/anatomy & histology , Dental Pulp Cavity/anatomy & histology , Dental Instruments , Odontometry/methods , Incisor/anatomy & histology , Root Canal Preparation , Data Interpretation, Statistical
16.
Rev. Círc. Argent. Odontol ; 70(216): 9-12, jun. 2013. graf
Article in Spanish | LILACS | ID: lil-689040

ABSTRACT

Las piezas dentarias permanentes jóvenes son aquellas que han tenido erupción reciente y cierre radicular apical incompleto. Existen diversos factores que pueden alterar la salud pulpar de los dientes, pero hay dos circunstancias que son particularmente nocivas: las caries profundas y las lesiones traumáticas, siendo en estos casos el tratamiento endodóntico necesario para conservar el órgano dental. Para establecer correctamente la longitud de trabajo, uno de los métodos más modernos es la utilización de localizadores apicales de 3ra generación. El objetivo de este trabajo fue estudiar la eficacia de un localizador apical de tercera generación en la determinación de la longitud de trabajo, in vivo, en piezas dentarias de 0 a 9 años posterupción. Materiales y métodos. Se estudiaron 366 conductos en 152 piezas dentarias de 0 a 9 años posterupción. Los conductos fueron medidos in vivo, obteniendo la longitud de trabajo por medio del localizador apical, para luego ser corroborada radiográficamente a través de la técnica de la bisectriz. Resultados y discusión. El localizador apical de 3ra generación resultó ser altamente eficaz en un 95 por ciento de los conductos estudiados. Dentro del grupo I (de 0 a 4 años posterupción), la lectura fue aceptable en un 91 por ciento y en el grupo iI (de 5 a 9 años posterupción) en un 95 por ciento. Se utilizó la prueba estadística de Chi-cuadrado, con corrección de Yates, no encontrándose diferencias significativas entre ambos grupos (p=0,05). Conclusiones. El localizador apical de 3ra generación estudiado es altamente confiable para determinar la medida de trabajo en tratamientos endodónticos de piezas dentarias permanentes de pacientes pediátricos.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Tooth Apex/anatomy & histology , Tooth Apex , Tooth Eruption/physiology , Odontometry/methods , Chi-Square Distribution , Dentition, Permanent , Root Canal Therapy , Data Interpretation, Statistical , Tooth Injuries/diagnosis